Mark-levinson Reference Preamplifier N32 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Odbiorniki i wzmacniacze Mark-levinson Reference Preamplifier N32. Mark Levinson Reference Preamplifier N32 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Owner’s Manual

Nº32ReferencePhono ModulesOwner’s ManualMadrigal Audio LaboratoriesR

Strona 2

10UnpackingWarning! Do not attempt to use your Nº32 Reference Phonomodules unless your Nº32 Controller is using version1.03 (or greater) of its operat

Strona 3 - Important Safety Instructions

11Operating VoltageThe Nº32 Reference Preamplifier is set at the factory (internally) for100V, 120V, 230V, 220V, or 240V AC mains operation @ 50 or 60

Strona 4

12Installing the Nº32 ReferencePhono Preamplifier ModulesImportant! Installation of the Nº32 Reference Phono PreampllifierModules should be done by a

Strona 5 - Table of Contents

13material needed The following materials and tools are needed to perform the installa-tion of the Nº32 Phono modules into the Nº32 Preamplifier:1 – N

Strona 6 - Nº32 Reference Preamplifier

143. Remove the two screws from rear bottom of Nº32 Preampli-fier top cover that hold it in place (using the 3⁄32” hex keysupplied with the Nº32).Thes

Strona 7

155. Peel off the protective film covering the copper strip on theend of the wrist strap, and attach it so that the copper stripcontacts the chassis o

Strona 8 - TONE ARM GROUND

16this , not Warning: The cables must lie flat against phono preamp topcover to slide in to Nº32 preamp.8. Gently slide the left phono preamp mod

Strona 9 - RIAA equalization

1711. Carefully lift connector ends of cables out of holes in phonopreamp top cover.Being careful to avoid catching the connectors on the edges of the

Strona 10 - Unpacking

18(closeup)13. Remove your ESD wrist strap from the chassi and from yourwrist.It would hinder your replacing the top cover, next.14. Replace Nº32 prea

Strona 11 - Operating Voltage

19Customizing Your Nº32setup overview The Nº32 Preamplifier has many provisions for custom-tailoring thesystem’s operation to match your preferences.

Strona 12 - Phono Preamplifier Modules

CAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DONOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE.REFER S

Strona 13

20Set Phono 1Name= PH/MC 1Ph Gain= +60Gain= +12 dBOffset= 0.0Bal= <-0.0->20Hz HPF=ONR Load=100C Load=.01uFSet Phono 2Name= PH/MM 2Ph Gain= +40G

Strona 14 - 32” hex key

21between the output level of a given source and thepreamplifier’s gain structure.• Offset— automatic volume adjustments implementedwhenever switching

Strona 15 - 64” hex)

22The Ph Gain selection should be made prior to the gain adjustmentoutlined below, as appropriate for your cartridge type. Otherwise youmay end up att

Strona 16 - 32” hex key)

23setting the balance The balance (Bal) setting is unique to the phono preamplifier, andshould be used to compensate for the small imbalances found in

Strona 17

24setting thecapacitive loadC Load refers to the capacitive load the phono preamplifier presents tothe cartridge. (Of course, any capacitance in the p

Strona 18

25Installing a Custom LoadA pair of gold plated screw terminals is available inside each of theNº32 phono preamplifier modules. It may be used to inst

Strona 19 - Customizing Your Nº32

261. Lift connector end of cable out of hole in shield box ifneeded.2. Using the 5⁄64" hex driver, remove four button head screwsfrom top cover o

Strona 20 - Bal= <-0.0->

275. Loosen each gold thumb screw a few turns.You do not have to remove the thumbscrews—just loosen themenough to slide the leads of your resistor in

Strona 21

289. Guide cables through holes and replace top cover.10. Re-install top cover screws.Be careful not to cross thread these relatively small screws.11.

Strona 22 - . For ex

29Care and MaintenanceTo remove dust from the external cabinet of the Nº32, use a featherduster. To remove dirt and fingerprints, we recommend isoprop

Strona 23 - 1 and for Phono 2

Important Safety InstructionsPlease read all instructions and precautions carefully and completely before operating your MarkLevinson® preamplifier.1.

Strona 24

30U.S. and Canadian Warranty90-day limited warranty This Mark Levinson® product is warranted to be free from defects inmaterial and workmanship under

Strona 25 - Installing a Custom Load

31Obtaining ServiceWe take␣ great pride in our dealers. Experience, dedication, and integritymake these professionals ideally suited to assist with ou

Strona 26

32SpecificationsThe correlation between published specifications and sonic quality is unreliable. A listof numbers reveals virtually nothing. All tech

Strona 27

33Installation Notes

Strona 28 - Preamplifier Modules

630357 © 3/1999 Madrigal Audio Laboratories, Inc. All rights reserved. Printed in U.S.A.is a registered trademark of Madrigal Audio Laboratories, Inc.

Strona 29 - Care and Maintenance

4From all of us at Madrigal Audio Laboratories, thank you for choosing the MarkLevinson Nº32 Reference Phono Preamplifier Modules.A great deal of effo

Strona 30 - U.S. and Canadian Warranty

5Table of ContentsSpecial Design Features of the Nº32 Reference Preamplifier ... 6modular approach ...

Strona 31 - Obtaining Service

6Special Design Features of theNº32 Reference Preamplifiermodular approach The Nº32 Reference Preamplifier and Reference Phono PreamplifierModules wer

Strona 32 - Specifications

7tion, optional custom termination is provided via a pair of gold-platedterminal posts within each phono module. No soldering is necessarywhen using t

Strona 33 - Installation Notes

8able from our balanced circuitry by including a balanced XLR inputconnector version of the phono preamplifier modules.123NC123NCLEFT +LEFT -TONE ARM

Strona 34 - MADRIGAL AUDIO LABORATORIES

9width and open loop gain to provide uncompromised performanceeven at the 60db of gain required by a moving coil preamplifier. Theinstrumentation ampl

Komentarze do niniejszej Instrukcji

Brak uwag